Ordering
D-DFP1-05-RA1 18cc D-DFP1-08-RA1 27cc
D-DFP1-11-RA1 36cc D-DFP1-12-RA1 40cc
D-DFP2-12-RA1 40cc D-DFP2-14-RA1 45cc
D-DFP2-17-RA1 55cc D-DFP2-19-RA1 60cc
D-DFP2-21-RA1 68cc
D-DFP3-21-RA1 69cc D-DFP3-25-RA1 82cc
D-DFP3-30-RA1 98cc D-DFP3-35-RA1 113cc
D-DFP3-38-RA1 122cc
|
Description
Group 1 vane pump SAE B flange CW rotation & 7/8" keyed shaft.
Group 1 vane pump SAE B flange CW rotation & 7/8" keyed shaft.
Group 2 vane pump SAE B flange CW rotation & 7/8" keyed shaft.
Group 2 vane pump SAE B flange CW rotation & 7/8" keyed shaft.
Group 2 vane pump SAE B flange CW rotation & 7/8" keyed shaft.
Group 3 vane pump SAE 4 flange CW rotation & 1.25" keyed shaft.
Group 3 vane pump SAE 4 flange CW rotation & 1.25" keyed shaft.
Group 3 vane pump SAE 4 flange CW rotation & 1.25" keyed shaft.
|
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system. |