Ordering
RV-CLRV-C
RV-CLRV-D
RV-CLRV-F
|
Description
Cross line mounted 3/8" BSP relief valve suitable for flows up to 36 litres per minute and adjustable up to a maximum of 210 bar
Cross line mounted 1/2" BSP relief valve suitable for flows up to 55 litres per minute and adjustable up to a maximum of 210 bar
Cross line mounted 3/4" BSP relief valve suitable for flows up to 100 litres per minute and adjustable up to a maximum of 210 bar |
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system. |