Ordering
DV-3C-C1
DV-3D-C1
DV-4C-OC
DV-4D-OC
DV-4C-CC
DV-4D-CC
|
Description
3 port diverter valve, closed centre condition c/w 3/8" BSP ports, flows up to 27 lpm at 210 bar
3 port diverter valve closed centre condition c/w 1/2" BSP ports, flows up to 45 lpm at 210 bar
4 port diverter valve, open centre condition c/w 3/8" BSP ports, flows up to 27 lpm at 210 bar
4 port diverter valve, open centre condition c/w 1/2" BSP ports, flows up to 45 lpm at 210 bar
4 port diverter valve, closed centre condition c/w 3/8" BSP ports, flows up to 27 lpm at 210 bar
4 port diverter valve, closed centre condition c/w 1/2" BSP ports, flows up to 45 lpm at 210 bar
|
Temperature
Oil temperature should be between +30ºC & +60ºC during normal operation. Oil life is greatly reduced if temperature exceeds 60ºC. As a general rule, oil life is halved for each 8ºC temperature exceeds 60ºC.
Filtering
It is necessary to keep the level of contamination within a hydraulic system at an acceptable level to ensure trouble free operation. Filtration should always be specified at a level that protects the most sensitive item or component in the system. |